10000 / 12000 BTU
Room Air Conditioner
with Heat Pump
OPERATING AND INSTALLATION MANUAL
Models: KC-30H / KC-35H
Thank you for selecting Soleus Air. To ensure proper
operation, please read this manual and keep it for
future reference.
Vue de la page 0
1 2 3 4 5 6 ... 21 22

Résumé du contenu

Page 1 - Room Air Conditioner

10000 / 12000 BTURoom Air Conditionerwith Heat Pump OPERATING AND INSTALLATION MANUAL Models: KC-30H / KC-35H Thank you for selec

Page 2 - TABLE OF CONTENTS

8INSTALLATION INSTRUCTIONSUnpackingRemove packaging materials Remove and dispose of/recycle all packaging materials. Remove tape and glue residue fr

Page 3 - Safety Information

9Attach Side Curtains1. Locate provided bag of screws. 2. Insert top and then bottom of right-hand curtain housing in top and bottom curtain guides on

Page 4 - Unpacking

104. Use a ³⁄₁₆" drill bit to drill 3 starter holes 1/2" deep through the 3 holes in the cabinet and into the windowsill. 5. Attach cabinet

Page 5 - Normal Care and Maintenance

11Option 1—Wood, metal or plastic moldingWhen you are using wood, metal or plastic molding, the wood frame should line up with inside wall as shown. O

Page 6

12Complete InstallationNOTE: Handle air conditioner gently. 1. Make sure the free end of the ground wire is outside of the cabinet.2. Insert air condi

Page 7 - INSTALLATION REQUIREMENTS

13General Operating InstructionsWhile operation of all units is similar, controls vary slightlyfrom model to model. Operating Controls section showsco

Page 8

Fan ControlOFF – Completely shuts off the unit. To prevent blowingfuses, wait two minutes after turning the unit off beforeturning it on again.LOW CO

Page 9 - Power Supply Cord

15 Before Calling Service The following is a list of problems that are sometimes encountered when using a room air conditioner. Possible cause

Page 10 - INSTALLATION INSTRUCTIONS

1622 3/5''21 1/3''5 4/5''15 3/8''Thru-wall Installation Instructions for GREE® brand Room Air ConditionerIntro

Page 11 - Top channell

1715 9/16"Electrical outlet must be located within 5-feetof this point.22 13/16"Dimensions of Finished OpeningMasonry ConstructionSee CAUTIO

Page 12 - 2 bubble on

TABLE OF CONTENTS INTRODUCTION……………………………..…………………………………….…...1 SAFETY INFORMATION………………………………………………...…………...

Page 13 - Install Wood Frame

18Installation in Wall Thicker Than 5 ½inchesThe side louvers in outer case provide ventilation to air con-ditioner compressor and fan motor and must

Page 14 - Complete Installation

19 Specifications Model KC-30H KC-35H Cooling Capacity (BTU/HR) 9500/9700 11400/11600 Heating Capacity (BTU/HR) 8300/8500 10100/10

Page 15 - 1/2" Diameter

20 Warranty Soleus International Inc. warrants the accompanying Soleus Air 10000 / 12000BTU Heat Pump Room Air Conditioner (KC-30H / KC-35H) to

Page 16 - Operating Controls

1 Introduction Room air conditioners cool, dehumidify, and filter air inside your home. Heat pump and electric heat models offer both

Page 17 - Before Calling Service

2OWNER'S PRODUCT IDENTIFICATIONMODEL NUMBERSERIAL NUMBERMANUFACTURING NUMBEROwner's NameAddressCity State Zip / / Date of Pu

Page 18 - for GREE

3NEMA No. 5-15P NEMA No. 5-15R 125V-15AMP 115VNEMA No. 6-15P NEMA No. 6-15R 250V-15AMP 230/208V ratedat 12 amperes orlessNEMA No. 6-20P NEMA No. 6-20R

Page 19 - Masonry Construction

4Note: The life of your unit may be greatly reduced if you livein a salt air or other corrosive type environment. Under theseconditions, the unit sh

Page 20 - /2-inches

5INSTALLATION REQUIREMENTSTools and PartsGather the required tools and parts before starting installation. Read and follow the instructions provided w

Page 21 - Specifications

6Window installation Window opening measurements: 27" min. to 39" max. (68.6 cm to 99 cm) opening width. 16¹⁄₄" min. (41.3 cm) openin

Page 22 - Warranty

7Recommended grounding methodThis air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a grounded 3 pron